Contrast-adjustable 3D-printed microCT phantoms
This technology combines resin-based additive manufacturing with adjustable X-ray attenuation to produce customized microCT reference objects and radiopaque markers. By incorporating an iodine-containing contrast agent into UV-curable resin, the geometry and X-ray contrast of the resulting structures can be tailored to specific imaging applications.
Cover picture: Lung tissue embedded in synthetic resin with printed radiopaque conical phantom.
Challenge
Micro computed tomography (microCT) enables three-dimensional imaging of biomedical samples based on differences in X-ray attenuation. Structures with similar attenuation are difficult to distinguish, making reference objects (phantoms) important for image interpretation and comparison.
The challenge is to provide a single customizable reference object for evaluating both spatial resolution and X-ray contrast. This requires combining fine, application-specific geometries with adjustable X-ray attenuation in a homogeneous material. Particles, sedimentation and trapped air can introduce artifacts that compromise high-resolution imaging.
Correlating microCT datasets with histological sections additionally requires reference markers that are clearly identifiable in both modalities and compatible with tissue embedding and histological processing.
Our Solution
The technology combines UV-curable resin with an iondine-containing contrast agent to produce customizable microCT reference structures. Adjusting the contrast-agent concentration tunes X-ray attenuation, while high-resolution 3D printing provides flexibility in marker geometry. The inventive concept integrates regions with different contrast levels into a single, continuous resin matrix, enabling spatial resolution and X-ray contrast to be addressed within one reference object.
Proof-of-concept demonstrators have shown distinct contrast levels and spatially varying attenuation. A four-chamber phantom containing different contrast-agent concentrations produced clearly distinguishable microCT signals. Further experiments using a two-component dispensing system demnonstrated contrast variation by changing the mixing ratio durng fabrication. These results establish the feasibility of the approach, while material homogeneity, dimensional stability and quantitative calibration remain areas for further development.
The technology also supports the alignment of microCT images with histological sectios. Contrast-containing, 3D-printed markers have been successfully embedded alongside lung tissue in methyl methacrylate (MMA). Their visibility in both imaging modalities and their conical geometry allow the position and orientation of histological sections to be determined within the 3D volume, providing the starting point for precise image registration and multimodal fusion (Figure 1).
Figure 1: Overview of the extended histological routine. Reference structures are first printed using a tunable UV-resin mixed with a contrast agent (A).
The resulting conical markers are embedded alongside the tissue specimen (lung punch biopsy, in this case) in resin (B). The polymerized block is then scanned using PBI-microCT (C) and subsequently sectioned (D).
After histological staining, the position of each individual 2D slice is determined using the conical markers and precisely registered to the corresponding in silico plane of the 3D volume (E), thereby facilitating a multimodal fusion of both datasets.
Advantages
- Customizable geometry and X-ray contrast: Marker shape and attenuation can be adapted to the imaging setup by modifying the digital design and contrast-agent concentration.
- Clear microCT visibility: Enhanced X-ray attenuation allows the printed markers to be distinguished from the surrounding MMA embedding resin, facilitating segmentation.
- Multimodal compatibility: The markers remain identifiable in both microCT images and histological sections, supporting spatial correlation of the datasets.
- Accessible fabrication: Demonstrated using a commercially available DLP printer without changes to its default printing settings.
Applications
- MicroCT–histology co-registration: Locating and orienting individual histological sections within three-dimensional microCT datasets.
- Correlative tissue analysis: Combining histological information with the three-dimensional structural context of the corresponding tissue region.
- Reference phantom development: Producing application-specific reference geometries with adjustable attenuation; multi-contrast and graded reference objects are under development for combined spatial-resolution and contrast assessment.
Development Status
Successful production of 3D X-ray phantoms with distinct and graded contrast levels, validated by microCT.
Refrences
Nolte, P. et al. Spatial correlation of 2D hard-tissue histology with 3D microCT scans through 3D printed phantoms. Sci Rep 13, 18479 (2023), https://doi.org/10.1038/s41598-023-45518-0.
Nolte, P. et al. X-ray contrast-adustable 3D printing for multimodal fusion of microCT and histology. Front. Med. Technol. 1702201 (2026), https://doi.org/10.3389/fmedt.2025.1702201.
Patent Status
IP rights (DE 10 2024 105 696.7) have been filed in the name of the Hochschule für angewandte Wissenschaft und Kunst Hildesheim/Holzminden/Göttingen (HAWK) and the Georg August Universität Göttingen, Universitätsmedizin (UMG) and a licensing partner is sought.